The Gillette SPVD-6000 Standby Generator offers a Volvo diesel engine, numerous three phase voltage options, and up to 600 kW of power.
Model | Phase, Voltage, Power Factor |
Standby Rating kW, kVA, Amps |
SPVD-6000-3-2 | 3 Phase, 120/208V, 0.8pf |
600kW, 750kVA, 2084A |
SPVD-6000-3-3 | 3 Phase, 120/240V, 0.8pf |
600kW, 750kVA, 1806A |
SPVD-6000-3-4 | 3 Phase, 277/480V, 0.8pf |
600kW, 750kVA, 903A |
SPVD-6000-3-5 | 3 Phase, 127/220V, 0.8pf |
600kW, 750kVA, 1970A |
SPVD-6000-3-16 | 3 Phase, 346/600V, 0.8pf |
600kW, 750kVA, 722A |
FEATURES
- All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
- Solid state, frequency compensated voltage regulation is standard.
- Basler DGC-2020 digital controller offers an integrated gen-set control system for single gen-set applications, and includes generator metering, engine-generator protections, exercise timer, and expansion capabilities. Controller has stop-run-auto mode buttons, menu scroll buttons, and a backlit LCD display.
- Heavy-duty circuit breaker is standard on all gen-sets.
- Battery tray, cables, straps, and charger included.
- Meets NFPA-110 Level 1 when equipped with the necessary accessories and installed per NFPA standards.
- UL-1446 and UL-2200 certified.
ENCLOSURE OPTIONS
- OPEN STYLE – No Enclosure: Gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer and flexible exhaust hose are not supplied , as installation requirements are not known. However, these two items are available as optional equipment.
- LEVEL 2 – Aluminum Housing: Full weather protection and superior sound attenuation for specific low noise applications. Critical grade silencer is standard. Average sound level of 83 dBA at 23 ft.
Enclosure | Dimensions (inches) L x W x H |
Weight (lbs) |
Open Style | 152 x 72 x 80 | 9825 |
Level 2 | 186 x 72 x 94 | 12325 |
DIESEL FUEL TANK OPTIONS
- Feature double-walls and emergency vents. Designed for generator sub-base installation. UL-142 Certified.
- Available in three sizes: 982, 1959, & 2938 gallons for 24, 48, or 72 hours of runtime at full load.
- Further descriptions and tank options available here.
- Generator can also be used with customer-supplied fuel tank.
DOWNLOADS
OPTIONS
- Engine Coolant Heater
- Starting Battery Heater Blankets
- 10A Battery Charger Upgrade
- 20A Battery Charger Upgrade
- Two 1000 CCA 12VDC Starting Batteries
- Emergency Stop Switch – mounted in a NEMA 4X small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- Emergency Stop Switch – mounted in a “Break Glass Station” NEMA 3R small enclosure, UL Listed, Suitable for remote locations, Complies with NFPA-110 requirements
- NFPA-110 Compliance Package: Includes 16 lamp dual (8) display remote annunciators (choice of flush-mount or surface-mount) and a heavy-duty 10A 12/24 VDC battery charger
- External Permanent Magnet Generator (PMG) for improved motor starting capabilities and un-interrupted excitation power
- External Permanent Magnet Generator (PMG) with Digital Voltage Regulator (DVR) for improved motor starting capabilities, un-interrupted excitation power, and RMS sensing
- Critical Grade Silencer Upgrade – for average sound level of 98 dBA at 23 ft with an Open Gen-Set (standard with Level 2 Enclosure)
- Hospital Grade Silencer Upgrade – for average sound level of 78 dBA at 23 ft in a Level 2 Enclosure
- R7 Foam Insulation (4-5 dBA sound reduction)
- Paralleling Package
- Stainless Steel Enclosure
- Generator Enclosure Lights
- Liquid Containment Pan – installed under frame base
- Spring Vibration Mounts
- Motorized Dampers
- Isolator Mounting Pads
- Enclosure Space Heater
- Controller Upgrades and Alarm Interfaces
- Asco 300 Automatic Transfer Switch (See Accessories Tab for a partial listing or follow this link for a full listing)
- Five Year Extended Warranty