The Simplex Merlin is a dual voltage (240/480V), fine load step resolution, fully instrumented portable resistive load bank intended for shop or field use by engine generator dealers and service shops for maintenance, testing, and performance proving of engine generator sets, UPS, and other power systems up to 200-400 KW (depending on the model).
FEATURES
- Load Capacity: Max capacity up to 200, 250, 300, 350, or 400kW at 240 and 480 VAC, 3PH, 60Hz. Capacity derates at other voltages.
- Duty Cycle: Rated for continuous operation.
- Load Step Resolution: 5kW minimum at 240 and 480 VAC, 3PH, 60Hz.
- Controls: Master load toggle switch and load step toggle switches; Digital meter; Fan Reversal, Load Voltage Selector, and Control Voltage Selector switches; Operator indicator lights: normal operation, over-voltage, fan failure / over-temperature.
- Merlin 200-300 Control/Fan Power: User selectable from internal 208-240V load or from external 115V 1PH 60Hz source – power cord included (see Options below).
- Merlin 350-400 Control/Fan Power: User selectable from internal 3PH load or from external 3PH 230/460V source.
- Cooling: Three phase 6000-8000 CFM direct drive fan; Cast aluminum air foil type, shrouder propeller fan; Horizontal airflow – cold air intake from front, hot air exhaust out the rear.
- Load Elements: Simplex Powr-Web chromium alloy, open wire, continuously supported, power resistor.
- System Protections: Sensors, alarms (alarm message on remote operator interface terminal), lock-outs as appropriate, for the following: fan failure, high exhaust temperature, high intake temperature, high interior temperature (sensed at three points);
- Load Circuit Protection: branch circuit fuses. One set of fuses each 50KW branch. Fuses are current limiting type, 200,000 AIC, 600V, enabling safe use on large generating or UPS system.
- Load Connection: 12′ connection cable set including 3-phase power cables and ground cable, stowed behind hinged door in rear compartment.
- Enclosure: Exceptionally rugged, all welded, formed steel chassis. Lifting eyes, forklift channels, casters, and moving handle.
Model | Max Capacity | Load Step Resolution | Dimensions HxWxD (inches) |
Weight (lbs.) |
Merlin 200 |
200 kW @ 240/480V 3Ph 150 kW @ 208/416V 3Ph 125 kW @ 190/380V 3Ph 134 kW @ 240V 1Ph |
5, 10, 10, 25, 50, 100 @ 240/480V 3Ph |
56 x 31 x 50 |
865 |
Merlin 250 |
250 kW @ 240/480V 3Ph 188 kW @ 208/416V 3Ph 157 kW @ 190/380V 3Ph 167 kW @ 240V 1Ph |
5, 10, 10, 25, 50, 50, 100 @ 240/480V 3Ph |
56 x 31 x 50 |
865 |
Merlin 300 |
300 kW @ 240/480V 3Ph 225 kW @ 208/416V 3Ph 188 kW @ 190/380V 3Ph 200 kW @ 240V 1Ph |
5, 10, 10, 25, 50, 100, 100 @ 240/480V 3Ph |
56 x 31 x 50 |
865 |
Merlin 350 |
350 kW @ 240/480V 3Ph 262 kW @ 208/416V 3Ph 219 kW @ 190/380V 3Ph 233 kW @ 240V 1Ph |
5, 10, 10, 25, 50, 50, 100, 100 @ 240/480V 3Ph |
69 x 31 x 50 |
1053 |
Merlin 400 |
400 kW @ 240/480V 3Ph 300 kW @ 208/416V 3Ph 250 kW @ 190/380V 3Ph 267 kW @ 240V 1Ph |
5, 10, 10, 25, 50, 100, 100, 100 @ 240/480V 3Ph |
69 x 31 x 50 |
1053 |
PRODUCT DOWNLOADS
Merlin Dimensions & Key Features
Simplex One-Year Parts Only Warranty
OPTIONS
- Merlin 200-300 Control/Fan Power also from Internal 480V Load (OPLB-71) – ADD $3,046.00
- Cam-lock Power Connections – Call for Pricing
Reviews
There are no reviews yet.