The Simplex Neptune 2.0 Stationary Outdoor Resistive Load Bank features a highly standardized, advanced design covering the 200-650 kW range at common three phase voltages up to 600VAC. Neptune 2.0 is a standard inventory item with versatile control and application possibilities.

Standard Neptune Models
Model Number:
NEPTUNE-
Max
Capacity
3-Phase
Voltage
Our Price
150-3-208 150 kW 208V $24,185.00
200-3-208 200 kW 208V $29,758.00
200-3-480 200 kW 480V $21,282.00
250-3-208 250 kW 208V $33,517.00
250-3-480 250 kW 480V $23,834.00
300-3-208 300 kW 208V $34,264.00
300-3-480 300 kW 480V $29,898.00
400-3-208 400 kW 208V $39,248.00
400-3-480 400 kW 480V $32,706.00
500-3-480 500 kW 480V $35,701.00
600-3-480 600 kW 480V $39,155.00

FEATURES

  • Standard Inventory Models: 150 kW at 208 VAC, 3Ph; 200, 250, 300, 350, 400, & 450 kW at 208, 480, or 600 VAC, 3Ph; and 500, 550, 600, & 650 kW at 480 or 600 VAC, 3Ph (Other kW and VAC options available up to 650 kW and 600 VAC).
  • Completely Self-contained, Free-standing Unit: Includes all resistive load elements, load control devices, load element branch circuit fuse protection, main load bus and terminals, cooling system, control power supply, unit controller and malfunction detection system and NEMA type enclosure.
  • Numerous Applications: Ideal for high capacity load testing of generators, UPS, and other AC power sources; periodic reliability exercise of standby generators; automatic load leveling and minimum load regulation; regenerative/reverse power protection, and other load bank applications.
  • Duty Cycle: Rated for continuous operation.
  • Load Step Resolution: 5kW minimum.
  • System Controls: Digitally controlled via an on-board PLC. Choice of local or remote control using a standard digital color touchscreen HMI. Remote control connection is simplified through use of RS-485 over shielded/twisted pair network cable (1000m). Local/remote HMI is housed in a weather/tamper resistant, lockable enclosure. Manual control via direct numeric keypad entry is standard.
  • Control Power: Internal from load bus via transformer.
  • Cooling: Integral forced air cooling system. Three phase, direct drive motor driving cast aluminum fan blade. Circuit breaker combination motor starter. Rain shedding exhaust hood. Cooling airflow through the enclosure is vertical with cold air intake at the bottom and hot air exhaust out the top.
  • Load Elements: Elements mounted in easily accessible, slide out trays; Simplex Powr-Web chromium alloy, open wire, continuously supported, power resistor; UL recognized.
  • Load Circuit Protection: branch circuit fuses. One set of fuses each 50KW branch. Fuses are current limiting type, 200,000 AIC, 600V, enabling safe use on large generating or UPS system.
  • System Protection/Malfunction Detection: Fan failure, high exhaust temperature, high intake temperature; lockout and alarm. Exhaust temperature indicated on screen.
  • Load Connection: Plated bus bar within an oversize terminal junction box.
  • Enclosure: Modular enclosure consists of three parts: power section, control section, and exhaust hood. Type 3R weatherproof power section includes load elements and cooling fan. Type 3R weatherproof control section is thermally and electrically isolated from resistive load power section. The rain shedding exhaust hood mounts on the top of the power section. The exhaust hood may be deleted and a duct flange provided for indoor applications where air is exhausted through a duct to the outdoors. The load bank enclosure is of double wall construction for cool exterior. All access via hinged doors with lockable latches. All exterior fasteners are stainless steel. Intake and exhaust openings are screened. Enclosure is powder-coated dark gray. Exhaust hood is powder-coated high temperature black.
  • National Fire Protection Association (NFPA): Satisfies the requirements for emergency stand-by power systems.
  • UL Listed.

PRODUCT DOWNLOADS

Neptune Brochure

Neptune Drawing (with Local Controller)

Neptune Drawing (with Remote Controller)

Neptune Installation Drawing

Neptune Field Connection Diagram

Neptune Technical Specs

Simplex One-Year Parts Only Warranty

OPTIONS

  • Automation with Auto-Load Regulation and Regenerative Power Protection (NEPTUNE-AUTO) – ADD $2,256.00
  • MODBUS TPS – replaces standard RS-485 (NEPTUNE-TCP) – ADD $1,004.00
  • Anti-condensation heaters with thermostatic control
  • Load Bank control and monitoring via BMS
  • External Fan/Control Power
  • Main load disconnect breaker or fused disconnect switch
  • Connection via cable in conduit, cable tray, cable duct, bus duct.
  • Indoor enclosure configuration with duct flange instead of exhaust hood.
  • Sound attenuation enclosure.
  • Highway Trailer: Construction conforms to applicable Federal and DOT standards. Includes: safety chains, electric lights, electric brakes, leaf springs, ball hitch coupler, lift jack and caster.
Voltage Options

60Hz Voltage Options

50Hz Voltage Options

Frequency Options

Load Steps

Control/Cooling Power

Airflow

Temperature

Dimensions HxWxD (inches)

Weight

Limited Warranty

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

ACCESSORIES